Electronic timer controlled condensate drain GTDV & GTDC
Draining the moisture from compressed air systems ensures less downtime and damage due to rust and scale. Gardner Denver drains are designed for long life and require minimum maintenance. They are critical components in the quest for system efficiency and reliability. When a drain fails to discharge the condensate, the condensate can carry over into the system, causing a build-up of contaminants in dryers, receivers and filters. On multiple stage compressors, moisture carryover from the intercooler may allow liquid into the next stage, causing premature wear and a potentially catastrophic failure.
Electronic timer controlled condensate drain
The GTDV timer controlled condensate drain is a combination of a solenoid valve and an electronic timer designed to automatically remove condensate from compressed air systems. The GTDC in addition, has an integral ball valve and a strainer, all in the same body.
Product features
The GTDV and GTDC are designed to remove condensate from compressors, compressed
air dryers, air filters and receivers up to any size, type or manufacturer.
The GTDV and GTDC offer true installation simplicity and they are recognised as the most reliable and best performing condensate drain worldwide. The larger orifice combined with its prominent front labelling feature is complemented by a selection of high pressure ranges and stainless steel valve options. In addition, virtually all voltage options are available in the GTDV and GTDC models.
Features & Benefits
• Any type of compressed air systemand compressor capacity
• Available in High Pressure up to 80 bar
• Environmentally friendly low Watt version available
• Serviceable valve construction
• Large (4.5mm) valve orifice
• Does not air-lock during operation
• Quick to service
• Test feature (micro-switch)
• Accurate time cycles
• High quality PCB components, offering you consistent quality
Technical Data
Max. compressor capacity |
Any size |
Min./max. system
pressure |
Standard: 0 - 16 bar HP: 0 - 80 bar |
Min./max. medium
temperature |
1 - 55°C (34 -
131°F) |
Min./max. ambient
temperature |
1 - 55°C (34 -
131°F) |
Supply voltage options |
115VAC / 230VAC |
Environmental protection |
IP65 (NEMA4) |
Connector type
(power) |
DIN 43650-A |
Inlet
connections |
GTDV: 1/4", 3/8", 1/2" BSP GTDC: 1/4", 1/2" BSP |
Outlet
connections |
GTDV: 1/4", 3/8", 1/2" BSP GTDC: 1/2" BSP |
Inlet connection height |
Approx. 1cm |
Valve type |
2/2 way,
direct acting |
Valve orifice |
GTDV: 4.5 mm GTDC: 4.0
mm |
Valve seals |
FPM |
Serviceable valve |
Yes |
Valve housing
material |
Brass (stainless steel available) |
Test feature |
Yes |
Timer cycle
range (ON/OFF) |
0.5 – 10 seconds / 0.5 – 45 minutes |
Timer PCB |
SMD technology, ensuring consistency in production |
Timer cycle
indication |
Bright LED illumination |