Call back
GDS-OFP compressed air preparation units

GDS-OFP compressed air preparation units

Installations for the preparation of compressed air for breathing GDS-OFP - Adsorption type respiratory air systems that provide the consumer with respiratory air in accordance with all international standards and medical requirements.

Gardner Denver GD-OF 0005-8750 series industrial dehumidification stations, with patented incoming air cooling technology and 7-step cleaning, with a capacity from 0.08 m3 / min to 145 m3 / min. Drainage stations are manufactured with built-in pre-micro and sub microfilters, and final filters for removing particulate matter, aerosols, carbon, odors and provide unsurpassed cleaning.

7-step cleaning ensures absolutely clean breathing air

Next, the catalyst (OX purification step) converts CO to CO2 and thus reduces the CO content to 1 ppm. The final PE filter retains adsorbent particles that can get into the air during the adsorption phase and / or during the catalytic process.


In the OFP installation, a seven-stage cleaning of compressed air is implemented:

1. Pre-filter MF - efficiency 99.99998% with respect to particles of 0.01 microns;

2. SMF fine filter - efficiency 99.99999% with respect to particles of 0.01 microns;

3. Adsorption dryer - residual moisture content - 0.11 g / m3;

4. Adsorber SP - residual CO2 content less than 300 ppm;

5. AK carbon filter - odor removal;

6. Catalyst OX - to bind CO and CO2;

7. Final PE filter - removal of solid particles larger than 5 microns.

Brands

Call back Catalog Online