Block Modular Compressor Gaseous Oxygen Station (Medical Oxygen)
Compressors International offers oxygen mobile stations for generating oxygen of 90-95% purity. The station includes air distribution complexes located in standard containers, which can be delivered and installed directly at the place of consumption. The container is equipped with a ventilation and heating system, as well as a fire safety system. The temperature regime in the container is maintained automatically.
Commissioning is carried out with a minimum number of operations, namely the supply of communications, power lines and compressed air pipework. Thanks to the Oxygen Modular Station, the medical centre is not dependent on oxygen suppliers, as it generates it independently.
Advantages of mobile oxygen stations:
- Fast start-up of oxygen production.
- Full automation and ease of maintenance.
- Modern oxygen generator and highly reliable compressors with a long service life.
- High level of safety.
- Modern ventilation and heating system.
- Low operating costs.
- Modern monitoring and control system.
- No special requirements for the premises.
- Ability to connect to an existing local network.
Complete set of the medical air station:
- Screw compressor with 2 or 3 times redundancy.
- Compressed air receiver: separate (vertical) or (integrated (multi-zone).
- Compressed air dryer: refrigerated (+3°C) or adsorption (-40°C).
- Air filtration unit: pre-filter, fine filter, carbon filter (0.003 mg/m3; 0.01 µm);
- Control and monitoring system.
Complete set of medical oxygen station:
- Screw compressor with 2 or 3 times redundancy.
- Compressed air receiver: separate (vertical) or integrated (horizontal).
- Compressed air dryer: refrigerated (+3°C) or adsorption (-40°C).
- Oxygen generator: oxygen generator.
- Sterile filter.
- Oxygen receiver.
- Air filtration unit: pre-filter, fine filter, carbon filter (0.003 mg/m3; 0.01 µm);
- Control and monitoring system.
Model |
Productivity |
Concentration, O2 |
Receiver, O2 |
Power supply |
Nm3/h |
% |
l |
V/Hz/ phase |
|
PO 40 |
2,3 |
93-95 |
150 |
230/50/1 |
PO 60 |
3,3 |
93-95 |
270 |
230/50/1 |
PO 90 |
5,0 |
93-95 |
270 |
230/50/1 |
PO150 |
8,1 |
93-95 |
270 |
230/50/1 |
PO 220 |
8,4 |
93-95 |
500 |
230/50/1 |
PO 270 |
11,0 |
93-95 |
500 |
230/50/1 |
PO 350 |
13,2 |
93-95 |
500 |
230/50/1 |
PO 500 |
16,8 |
93-95 |
1000 |
230/50/1 |
PO750 |
26,6 |
93-95 |
1000 |
230/50/1 |
Capacity
(Nm³/h) |
|
|
|
Oxygen
content (%): |
90,0 |
93,0 |
95,0 |
PO 20 |
1,2 |
1,1 |
1,0 |
PO 40 |
2,5 |
2,3 |
2,0 |
PO 60 |
3,6 |
3,3 |
3,0 |
PO 90 |
5,4 |
5,0 |
4,3 |
PO 150 |
7,8 |
7,2 |
6,7 |
PO 220 |
9,0 |
8,4 |
7,5 |
PO 270 |
12,0 |
11,0 |
10,0 |
PO 350 |
14,5 |
13,2 |
12,0 |
PO 500 |
18,5 |
16,8 |
15,5 |
PO 750 |
29,3 |
26,6 |
24,2 |
PO 1000 |
36,0 |
34,0 |
31,0 |
PO 1500 |
54,0 |
50,0 |
45,0 |
PO 2000 |
74,0 |
67,0 |
61,0 |