Sokratherm CHP Unit GG 140 is a modern cogeneration unit that produces heat and power on-site, without transport losses. Due to its high efficiency and ability to quickly turn on and off, this unit is an ideal solution for stabilizing the energy grid and balancing fluctuations in renewable energy production.

Characteristic Value
Engine type E3262 E302
Electrical power [kW] 263
Thermal power [kW] 394
Gas consumption [kW Hi] 710
Electrical efficiency [%] 37.0
Thermal efficiency [%] 55.5
Total efficiency [%] 92.5
Power to heat ratio 0.65
Primary energy factor 0.163
Service interval [operating hours] 1500
Major overhaul after [hours] 50000
Length [mm] 3600
Width [mm] 1500
Height [mm] 2340
Operating weight [kg] 6750
Noise level [dB (A) at 1 m] 74

Cogeneration and Trigeneration: What They Are and Their Benefits

Cogeneration is the simultaneous production of heat and electricity from a single energy source, significantly increasing overall fuel efficiency. Trigeneration additionally includes the production of cooling, making this approach even more versatile and efficient.

Benefits of Cogeneration:

  1. High fuel efficiency.
  2. Reduced energy costs.
  3. Minimal energy transport losses.
  4. Quick response to demand changes.

How Cogeneration and Trigeneration Work

A cogeneration unit operates on an internal combustion engine that drives a generator. The generated electricity is used on-site or fed into the grid, while the heat produced during combustion is used for heating, hot water supply, or industrial needs. In trigeneration, the additional heat is used to produce cooling via absorption chillers.

Advantages of Cogeneration Compared to Traditional Energy Production Methods

  1. Higher Efficiency: Cogeneration uses up to 90% of the fuel energy, whereas traditional methods use only about 50%.
  2. Flexibility: The ability to quickly turn on and off allows for better response to demand changes.
  3. Cost Savings: Reduced energy costs and lower infrastructure expenses.

Environmental Benefits of Cogeneration and Trigeneration

  1. Reduced CO2 Emissions: Higher fuel efficiency results in lower greenhouse gas emissions.
  2. Minimized Heat Losses: Using heat that is usually wasted reduces overall fuel consumption.
  3. Support for Renewable Energy: Stabilizing the grid during fluctuations in renewable energy production.

CHP (Combined Heat and Power Generation): What It Is

CHP, or cogeneration, is a technology that allows simultaneous production of heat and electricity from a single fuel source. The core component of a CHP unit is an internal combustion engine that drives a generator. The electricity can be consumed on-site or fed into the grid, while the heat is used for various needs such as heating and hot water supply.

Unit Sizes

To ensure high annual utilization, cogeneration units are typically sized based on the base heat load of the facility. This approach covers a significant portion of energy consumption, often more than half of the annual heat and power needs. Peak demands are covered by public grids and peak boilers.

Control Systems

The control system for CHP units from Sokratherm ensures complete control and automation of the cogeneration units' operation. It includes real-time monitoring and control functions, maximizing the efficiency and reliability of the units.

Advantages of Sokratherm CHP Units

  1. Compact Design: Ideal for installation in confined spaces.
  2. Minimal Installation Costs: Due to ready-to-connect construction with an integrated control panel.
  3. High Efficiency: Optimal use of fuel energy.
  4. Environmental Friendliness: Operating the engine in the range with the lowest emissions.
  5. Low Noise Levels: Excellent sound insulation and vibration decoupling.
  6. Automation: Fully automatic operation with internet-based remote monitoring and control.
  7. Reliability: High reliability and low operating and maintenance costs.

Increasing Thermal Efficiency with Condensing Heat Exchangers

At especially low return temperatures (below approximately 50°C), it is often sensible to gain additional heat from the exhaust gases. This can increase the regular thermal power of the unit by up to 15%, raising the total efficiency by several percentage points.

Cooling in Trigeneration

Our cogeneration units can be equipped with a 'Hot Cooling' function, allowing operation at increased flow temperatures up to 95°C. This is necessary for optimal operation of absorption chillers and other processes.

Installation in Containers or Substations

For special application cases, we offer our cogeneration units in weatherproof containers or concrete blocks, allowing them to be placed outside the main buildings.

Steam Production

The heat generated by a cogeneration unit can be used to produce steam, necessary for industrial processes such as in food processing or breweries.

Emergency Power Supply

Our cogeneration units can provide emergency power by operating in island mode, supplying critical systems during a mains failure.

Buffer Heat Storage

Buffer heat storages improve the operation and profitability of cogeneration units by absorbing excess heat and providing it when needed. This enhances the efficiency and economic viability of the units.

Grid Control

The zero feed-in control ensures that the unit does not feed electricity into the public grid, adjusting production to match on-site consumption.

Compact cogeneration unit with synchronous alternator to generate three-phase current 400 V, 50 Hz and heating water at a temperature level 90/70 °C. Operates on natural gas, with a three-way catalytic converter for low-emission λ = 1 operation, emission values according to BImSchG § 22. The performance data is valid for an altitude of up to 2000 m above sea level and an air temperature of up to 30 °C.

Operating Mode Electric Power (gross) Internal Consumption * Electric Power (net) Minimum Electric Power (partial load) Heating Power (tolerance 8 %) Gas Input (tolerance 5 %)
Mains Parallel Mode 206 kW 7 kW 199 kW 103 kW 323 kW 574 kW
Standby Power System 234 kVA       294 kW 522 kW

*) without external consumers, preliminary fuse in separate feed (if required): 63 A

Design and Scope of Supply

Engine with Accessories

  • Engine Type: MAN E3262 E302
  • Combustion Method: Gas Engine
  • Cycle: 4-stroke
  • Number/Design of Cylinders: 12 / V-assembly
  • Bore/Lift: 132/157 mm
  • Displacement: 25.78 dm³
  • Rotation Speed: 1500 rpm
  • Average Piston Speed: 7.85 m/s
  • Average Effective Pressure: 6.67 bar
  • Compression Ratio: 12:1
  • ISO Standard Rating per DIN ISO 3046-1: 215 kW
  • Specific Full Load Consumption: 2.67 kWh/kWh
  • Full Load Consumption at Hi (Net Calorific) = 10 kWh/Nm³: 57.4 Nm³/h
  • Average Synthetic Oil Consumption (estimated): 100 g/h

Engine Description:

  • Crankcase: with cylinder block made from one piece of cast iron, closed from below by oil tray.
  • Single Cylinder Head: with integrated cooling water and oil ducts.
  • Valves: arranged hanging, two valves one for outlet, valve stems made from carbide metal.
  • Pistons: light-alloy, cooled by pressurized oil stream via oil nozzles.
  • Crankshaft: with seven bearings and screw-on counterweights.
  • Intake Manifold: double flow, water-cooled.
  • Exhaust Fume Collector: water-cooled, leading to the exhaust heat exchanger.
  • Oil Pump: for pressure lubrication, tandem lube oil filter in main flow, cooling by oil cooler.
  • Air Intake: via dry filter from the engine room.
  • Crankcase Breather: with oil separator valve and connection to the air intake.
  • Cooling Water Circuit: closed, with electrical three-phase circulating pump 400 V, safety valve and expansion tank with pressure gauge for engine cooling.
  • Electrical Starter: 24 V, 7 kW.
  • Ignition System: microprocessor-controlled, with one ignition coil per cylinder.

Gas Supply

Safety gas line according to DVGW-VP 109, vibration-decoupled connection with support angles on the roof of the sound-absorbing case, consisting of ball valve with thermal shutoff, filter, pressure gauge with push-button valve, two solenoid valves, pressure control valve, gas regulation valve, and flexible connecting tube, certified by DVGW. Gas/air mixer with static Venturi insert, electronic speed governor.

Gas Supply and Catalyst

  • Lambda Sensor: for automatic regulation of the air/fuel ratio.
  • Catalyst: for emission reduction according to German BImSchG standards, built as a three-way catalytic converter for lambda = 1 operation.

Exhaust Silencer

Primary and secondary exhaust silencer made of stainless steel to reduce the exhaust noise level as recommended accessories for on-site installation.

Alternator

Synchronous alternator with inner pole, air-cooled, protection class IP 23, build design B3/B14 according to VDE 0530, radio suppression grade N. Synchronous alternator with integrated field coil, absorber cage and compound, brushless, two-layer winding, low harmonic content design, insulation class H.

  • Rated Output: 465 kVA
  • Rated Current (nom. power, cos φ 0.8): 372 A
  • Efficiency Rate (nom. power): 95.7 %
  • Cos φ: 1.0
  • Operating Mode: Star
  • Ambient Temperature, Max.: 40 °C
  • Voltage: 400/231 V
  • Frequency / Rotation Speed: 50 Hz / 1500 rpm

Coupling

Engine and alternator connected rigidly by SAE housing and interconnecting flange. Flexible coupling between engine flywheel and alternator shaft. Replacing the flexible intermediate ring is possible without disassembling both engine and alternator.

Base Frame and Pipework

Base frame as torsion-resistant, versatile profile steel construction used to carry engine/alternator as well as the following components of the CHP unit:

  • pump for engine cooling circuit,
  • heat exchangers for engine cooling circuit and exhaust,

Mounted ready for operation in the base frame, with complete pipework and insulated as far as required. All condensate lines are combined to one common outlet. If required for mounting in the heating water return: heating water circulating pump and 3-way valve for return temperature lifting, designed for operating data according to para. 3.5.

Sound-Absorbing Case

Powder-coated steel plate casing with highly effective sound-absorbing lining with elastic supporting and a controlled fan for ventilation of the canopy. Easily accessible due to removable cowls on all sides with quick-lock mechanisms. Base frame decoupled with Sylomer strips from the canopy.

Switch Cabinet

Integrated switch cabinet with power section according to VDE AR-N 4110:2018, on request VDE AR-N 4105:2018 (grid monitoring, synchronization), iPC for unit control and monitoring (with 10.1'' color TFT touchscreen display, opt. 15.6''), including control "MiniManager", optional remote monitoring system "RemoteManager", ready to use and wired.

Cooling Water Heat Exchanger

The engine cooling water heat is transferred to the heating water via a plate heat exchanger.

  • Material: 1.4401
  • Thermal Output from Engine Cooling (8 % tolerance): 203 kW
  • Heating Water Temperature Inlet/Outlet: 70/83 °C
  • Pressure Drop (Heating Circuit): 380 mbar
  • Cooling Water Temperature Inlet/Outlet (as new condition): 80/86 °C
  • Flow Rate (Engine Cooling Circuit): 36.8 m³/h
  • Cooling Water Pump Load: 3.8 kW

Exhaust Heat Exchanger

The exhaust heat of the engine is transmitted to the heating water through a water-cooled exhaust collector pipe and a tube-type exhaust heat exchanger.

  • Material: 1.4571 / P235
  • Thermal Output (8 % tolerance): 120 kW
  • Exhaust Gas Temperature Inlet/Outlet (as new condition): 570/100 °C
  • Heating Water Temperature Inlet/Outlet: 83/90 °C
  • Pressure Drop (Exhaust Side): 15 mbar
  • Pressure Drop (Heating Circuit): 170 mbar

If required, an additional exhaust gas heat exchanger is available for use of condensation heat, mounting on side of customer. The additional heat output of this heat exchanger (components touching the exhaust gas made of stainless steel 1.4571) is up to 57 kW.

Technical Data and Elucidations for Planning and Operation

Fuel

Natural gas of normal composition, free of phosphorus, sulfur, halogens, arsenic and heavy metals, as well as solids and liquids, with constant fuel value and pressure and according to the rules of the DVGW sheet G260.

  • Lower Limit for Lower Calorific Value (Hi): 10 kWh/Nm³
  • Methane Number: > 80
  • Permissible Hydrogen Content in Natural Gas (mixture): max. 20 Vol.%
  • Gas Flow Pressure Range (overpressure, constantly): 20 - 100 mbar
  • Gas Temperature: 10 - 30 °C

Operating values for other fuel compositions and conditions on request. We recommend using a gas warning system in the operating room (on side of customer).

Combustion Air and Ventilation

  • Combustion Air Requirement: 544 Nm³/h
  • Air Supply, in Total: 5450 m³/h
  • Inlet Air Temperature Min./Max.: 10/30 °C
  • Heat Radiation from Casing Surface: approximately 5 kW
  • Heat Ventilation from Within Casing: approximately 27 kW
  • Exhaust Air: 4900 m³/h
  • Exhaust Air Temperature: 50 °C
  • Free Pressing of Exhaust Air Fan at Operating Point (max.): 250 (685) Pa
  • Electric Load of Fan at Operating Point (max.): 913 (1960) W

Highly efficient radial fan (according to ErP2015) with EC-motor and temperature-controlled regulation, if required with connection box. Operating ventilation system above standard conditions not possible and leads to increased power consumption, sound level and operating temperature.

Exhaust Gas

  • Exhaust Gas Flow Rate at 100 °C: 865 m³/h
  • Permitted Back Pressure after Unit: 20 mbar

A continuous condensate drain must be installed in the connected exhaust gas system. For multi-unit systems each unit has to be equipped with a separate exhaust gas system.

Sound Levels

  • Sound Level of Engine (with/without sound-absorbing case): 74/87 dB(A)
  • Exhaust Sound Level after Optional Exhaust Gas Silencer: 78 dB(A)
  • Exhaust Sound Level after Optional Secondary Exhaust Silencer: 60 dB(A)
  • Ventilation Air Sound Level after Fan (Operating Point): 66 dB(A)

Free-field sound pressure values in 1 m distance. The triple shock absorption of the CHP-unit reduces the impact sound transmission to a minimum. A foundation for installing the CHP is not necessary if the engine room floor is able to carry the load of the CHP-unit and the unit is set on the foundation plate of the building.

Heat Production

The cooling water heat and the exhaust heat both have to be utilized over all possible operating points. Layout data:

  • Return-Temperature to Unit (Min./Max.): 60/70 °C
  • Standard Flow Rate: 13.9 m³/h
  • Max./Standard Temperature Increase: 30/20 K
  • Pressure Drop: 0.55 bar
  • Operating Pressure (Min./Max.): 1.5/6 (optional 10) bar

The return connection has to be equipped with a strainer with a mesh size of 0.25 mm.

Filling Quantities and Quality Demands

  • Oil Tray: 90 liters
  • Oil Storage Tank: 120 liters
  • Engine and Heat Exchanger Coolant: 80 liters

(Lubricating oil and coolant have to fit separate release lists.)

  • Heating Water: 130 liters

Treatment of the contents, additional and rotating heating water according to VDI guideline 2035 (group 4) with the following limits:

  • Total Earth-Alkaline /Total Hardness: < 0.02 mol/m³ / < 0.1 °dH
  • pH-Value: 9 - 10.5
  • Molecular Conductance (at 25 °C): < 250 μS/cm
  • Oxygen Content: < 0.02 mg/l
  • Chloride Content: < 20 mg/l
  • Filterable Substances: < 2 mg/l

Appearance: colorless, clear, and free of mechanical impurities. Use of oxygen binders should be avoided if possible.

Dimensions, Connections and Weight

  • Length (Basic Measurements): 3600 mm
  • Width: 1500 mm
  • Height: 2340 mm
  • Operating Weight: 6750 kg
  • Dry Weight: 6360 kg
  • Heating Water Inlet/Outlet: DN 65 (PN 10)
  • Gas Regulation Unit: R 2" (i)
  • Condensate: R ½" (a)
  • Exhaust (Flange): DN 150 (PN 10)

Brands