Call back

GDFT Activated Carbon Tower Range

Delivering “oil-free air” from oillubricated and oil-free compressors

Manufactured by Gardner Denver, the activated carbon tower practically eliminates all oil vapour and hydrocarbon odors from your operations. They are available in two configurations – aluminium extrusion and fabricated tank, are supplied with dust post-filter and are easy to maintain.

In critical applications like food and pharmaceutical production where oil content ISO8573-1 Class 1 air or better is crucial, this carbon adsorption technology helps achieve the highest quality “technically oil-free air”.

Extruded aluminium units are up to model GDFT58L and are lightweight (GDFT5 can be wallmounted). As per the tank configuration, they can be used in compressed air systems or at the point of use. Rightsizing units with corrective factors ensures consistent outlet air quality over 12 months of continuous operations.

GDFT Activated Carbon Tower benefits are your advantages:

Unparalleled Air Quality Guaranteed
Gardner Denver’s carbon tower offers you Class 1 air or better “technically oil-free air” when used with GDFT filters, 0.003 mg/m3 remaining oil content represents Class 0 air.

No expensive cartridges
Unique loose-fill adsorbent carbon filtration is much more cost-efficient than cartridges for a
lower total cost of ownership (TCO). Helps to protect the environment avoiding cartridge waste.

Flexible application
The carbon tower can be used with oil-lubricated or oil-free compressors, either at the point of use or as an air system component.

This activated carbon tower is a cost-effective, adaptable solution to your oil-free compressed air requirements from the experts at Gardner Denver.

Technical Data

Model

Part Number
(CCN)

Flow capacity

Pressure

Dimension
(mm)

In/out
connection

Weight

m3/h   

m3/min  

bar g

A        

B      

C       

inch (")

kg

GDFT5L   

47745965001  

30

0.50

14

749

212

143

3/8"

8

GDFT12L

47745966001

75

1.25

14

890

267

255

3/4"

20

GDFT18L

47745967001

110

1.83

14

1090

267

255

3/4"

24

GDFT25L

47745968001

150

2.50

14

1440

267

255

1"

32

GDFT30L

47745969001

180

3.00

14

1640

267

255

1"

35

GDFT58L

47745970001

350

5.83

14

1660

447

255

1-1/2"

70

GDFT100L   

47745971001

600

10.00

15

2113

391

391

2"

115

GDFT166L

47745972001

1000

16.67

15

2148

436

436

2"

157

GDFT260L

47745973001

1560

26.00

15

2463

483

483

3"

222

GDFT383L

47745974001

2300

38.33

15

2693

595

595

3"

379

GDFT466L

47745975001

2800

46.67

13

2879

721

721

DN100 PN40

456

GDFT950L

47745976001

5700

95.00

13

3455

855

855

DN150 PN40

900



ICT Correction factors

°C/bar g

4

5

6

7

8

9

10

11

12

13

14

15

25°C

0.63

0.75

0.88

0.88

1

1

1

1.14

1.14

1.14

1.25

1.25

30°C

0.63

0.75

0.88

0.88

1

1

1

1.14

1.14

1.14

1.25

1.25

35°C

0.63

0.75

0.88

0.88

1

1

1

1.14

1.14

1.14

1.25

1.25

40°C

0.55

0.66

0.77

0.77

0.88

0.88

0.88

1

1

1

1.11

1.11

45°C

0.45

0.54

0.63

0.63

0.72

0.72

0.72

0.81

0.81

0.81

0.9

0.9

50°C

0.32 

0.39 

0.45 

0.45 

0.52 

0.52 

0.52 

0.58 

0.58 

0.58 

0.65 

 0.65


Calculation for correct Activated Carbon Tower Air flow

= Nominal Activated Carbon Tower Air Flow x Correction Factor

Brands